Determination of Ni(II) in alloys using a new reagent derived from L-dopa
PDF (English)

Palavras-chave

Chromogenic reagent
Ni(II) quantification
Co and Ti interferents

Como Citar

Barreto, W. J., Magosso, H. A., Soares, M. F., Oliveira Silveira, B. M., Spacino Scarminio, I., Norio Ishikawa, D., & Giancoli Barreto, S. R. (2014). Determination of Ni(II) in alloys using a new reagent derived from L-dopa. Eclética Química, 36(3), 15–20. https://doi.org/10.26850/1678-4618eqj.v36.3.2011.p15-20

Resumo

A simple and sensitive UV-Vis spectrophotometric method was developed using a new chromogenic reagent, L-dopasemiquinone, for the quantification of Ni(II) in metallic alloys: Inox, Co-Cr, and Ni-Ti. The complex [Ni(II)(L1-)3]1- presents an intense band at 591 nm, ε = 2.4 x 103 L mol-1 cm-1. Beer’s law is obeyed from 4.02 x 10-5 to 2.01 x 10-4 mol L-1 with limits of detection and quantification of 4.15 x 10-5 mol L-1 and 5.02 x 10-5 mol L-1, respectively. The method was compared with atomic absorption spectrophotometry and inductively coupled plasma atomic emission spectroscopy obtaining good results. Cobalt and Titanium cause low interference in the method.

https://doi.org/10.26850/1678-4618eqj.v36.3.2011.p15-20
PDF (English)
Creative Commons License
Este trabalho está licenciado sob uma licença Creative Commons Attribution 4.0 International License.

Copyright (c) 2017 Eclética Química

Métricas

Carregando Métricas ...